Branches GUR-T and GUR-Y

Junction components are required for merging or splitting conveying flows. Outlets in small nominal widths are also required in pipelines for cleaning or for connecting measuring devices. With T-pieces GUR-T and Y-pieces GUR-Y the rubber pipe system covers almost all requirements. Compared to steel or plastic pipes, only larger minimum lengths (m, n , L2 in the sectional view) have to be observed.

Several outlets from a main pipe can be combined in one component (see middle sectional drawing). The base pipe can also have the same length and stiffness as a straight rubber pipe GUR. This reduces the number of components and allows cost-effective solutions .

Combination of branches GUR-T and GUR-Y
Combination of branches GUR-T and GUR-Y
sectional drawing of branches GUR-T and GUR-Y
α=90° α=30° α=45° α=60° α=60° α=90° α=120°
ND1 ND2 α mmin=Lmin mmin=Lmin ND mmin mmin mmin Connections
= nmin nmin = 0,75 x mmin
[mm] [mm] [°] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
40
25 <= ND2 <= ND1
15 <= α <= 90
200 694 471 359 40 361 246 187
loose flanges (types FL,FLR)
fixed flanges (type FR)
50 200 722 488 371 50 371 252 191
65 200 760 213 388 65 388 262 197
80 220 790 533 403 80 403 271 203
100 240 827 557 421 100 421 281 209
125 270 885 595 449 125 449 298 220
150 300 950 637 479 150 479 316 230
200 340 1055 706 528 200 528 345 248
250 380 1159 774 578 250 578 380 265
300 420 1253 834 621 300 621 410 280
350 450 -- 907 673 350 675 440 299
400 480 -- -- 725 400 731 470 320
500 540 -- -- -- 500 828 530 355
600 590 -- -- -- 600 929 600 390

The data given are guidelines. We would be happy to check your requirements for feasibility.

You would like to get advice on your application or to inquire a product ?


Just send the contact form and we will reply as soon as possible.

Consent Form*

Detailed information on handling user data can be found in our Privacy Policy